error Fusing temperature 541

541Fusing thermistor open (center)
The temperature of the hot roller remained below 0C for 5 sec at the center of the hot roller.• Fusing thermistor out of its position because of incorrect installation • Fusing thermistor disconnected or defective • Power supply not within rated range (15% or more below rating)
542Fusing temperature warm-up error (center)
The fusing temperature did not reach the standby temperature within 20 sec. at the center of the hot roller after the main switch turned on.• Fusing thermistor defective or out of position • Fusing lamp disconnected • Thermistor defective • Fusing lamp defective
543Fusing overheat error 1 (center)
The fusing thermistor detected a fusing temperature over 230 °C for 5 sec. at the center of the hot roller.• TRIAC short on PSU (PSU defective) • BCU board defective • Fusing thermistor defective
544Fusing overheat error 2 (center)
A fusing temperature over 250 °C is detected at the center of the hot roller by the fusing temperature monitor circuit in the BCU board. The power was interrupted for more than 0.3 sec.• TRIAC short on PSU (PSU defective) • BCU board defective • Fusing thermistor defective • Power supply voltage unstable
545Fusing overheat error 3 (center)
After warmup, the center of the hot roller attained full operating temperature and maintained this temperature for 10 sec. without the hot roller rotating.• Center hot roller thermistor installed incorrectly, disconnected. • Center hot roller thermistor defective
547Zero cross signal detection error
Zero cross signals were not detected within the prescribed time.• PSU, BCU harness loose or broken • PSU defective • BCU defective
551Fusing thermistor open (end)
The temperature of the hot roller remained below 0C for 5 sec. at the end of the hot roller.• Fusing thermistor out of its position because of incorrect installation • Fusing thermistor disconnected or defective • Power supply not within rated range (15% or more below rating)
552Fusing temperature warm-up error (end)
The fusing temperature did not reach the standby temperature within 20 sec. at the center of the hot roller after the main switch turned on.• Fusing thermistor defective or out of position • Fusing lamp disconnected • Thermistor defective • Fusing lamp defective
553Fusing overheat error 1 (end)
The fusing thermistor detected a fusing temperature over 230 °C for 5 sec. at the center of the hot roller.• TRIAC short on PSU (PSU defective) • BCU board defective • Fusing thermistor defective
554Fusing overheat error 2 (end)
A fusing temperature over 250 °C is detected at the center of the hot roller by the fusing temperature monitor circuit in the BCU board. The power was interrupted for more than 0.3 sec.• TRIAC short on PSU (PSU defective) • BCU board defective • Fusing thermistor defective • Power supply voltage unstable
555Fusing overheat error 3 (end)
After warmup, the center of the hot roller attained full operating temperature and maintained this temperature for 10 sec. without the hot roller rotating.• Center hot roller thermistor installed incorrectly, disconnected. • Ce