401Transfer roller leak error 1
A transfer roller current leak signal wad detected. (The current feedback signal for the transfer roller was not detected within the correct time.)• High voltage supply board set incorrectly or defective • Transfer roller set incorrectly or damaged • Transfer unit set incorrectly
402Transfer roller leak error 2
A transfer roller current leak signal is detected. The current feedback signal for the transfer roller is not detected within the correct time.• Transfer roller set incorrectly or damaged • High voltage supply board set incorrectly or defective
411Separation bias leak error
A separation bias leak signal was detected.• High voltage supply board defective • Discharge plate defective
490Toner supply motor leak error
More than 1 ampere supplied to the toner supply motor for longer than 200 ms.• Toner supply motor defective